@Rain Bird Corp I am trying to use some swing pipe type tubing to move a 5000 series rotor from behind a tree. I initially planned to remove the tree. The plan changed. Is there a max length of run and/or a friction pressure loss chart. I called rainbird tech support and couldn't get an answer after being on hold for 15 minutes. Can you help me out on this?

Last edited by Movingshrub on Tue Aug 07, 2018 6:54 pm, edited 1 time in total.


User avatar

g-man
Moderator
Posts: 14686
Joined: Wed Jun 14, 2017 10:32 pm
Location: Fishers, IN
Grass Type: Front: NoMix Back: Bewitched
Lawn Size: 5678
Mower: John Deere 220E

Re: Swing pipe max length

Post by g-man »

He will need to know your GPM on that head and the length you are planning to have from the lateral and your psi.


User avatar

Rain Bird Corp
Posts: 35
Joined: Wed Jun 06, 2018 10:27 am
Location: Worldwide
Grass Type: All Types
Lawn Size: ???
Mower: ????

Re: Swing pipe max length

Post by Rain Bird Corp »

Movingshrub wrote: ↑

Tue Aug 07, 2018 6:53 pm

@Rain Bird Corp I am trying to use some swing pipe type tubing to move a 5000 series rotor from behind a tree. I initially planned to remove the tree. The plan changed. Is there a max length of run and/or a friction pressure loss chart. I called rainbird tech support and couldn't get an answer after being on hold for 15 minutes. Can you help me out on this?

I will do what I can. It was not intended for this purpose. Why not just use pipe?

Ron Wolfarth
Rain Bird Corporation
6991 E. Southpoint Road
Tucson, Arizona 85756


Topic Author

Movingshrub
Posts: 3266
Joined: Mon Jun 12, 2017 11:31 am
Location: Huntsville, AL
Grass Type: TifTuf Bermuda
Lawn Size: 13,000 SQFT
Mower: Honda Rotary & JD 220A Reel

Re: Swing pipe max length

Post by Movingshrub »

I am going to ask you guys not to be jealous of my killer hand writing.

I planned to remove a tree that is 6' from a rotor. It's blocking the throw of water. The tree may be removed at some point. I am looking to move the rotor in front of the tree so as to had an unobstruxted path. I can either use 15' of flex pipe or 8' of PVC. The pvc route involves significantly more digging, depth wise, and digging through estblished grass, and both options involve the chance of running into tree roots. The flex pipe is easier also due to not having to cut and glue a new joint that is 18+" deep.
Image

Last edited by Movingshrub on Tue Aug 07, 2018 8:43 pm, edited 1 time in total.


Topic Author

Movingshrub
Posts: 3266
Joined: Mon Jun 12, 2017 11:31 am
Location: Huntsville, AL
Grass Type: TifTuf Bermuda
Lawn Size: 13,000 SQFT
Mower: Honda Rotary & JD 220A Reel

Re: Swing pipe max length

Post by Movingshrub »

Overall system PSI is 80. I am unsure what the PSI is after running through the DVF 100 valves to this point. I am using SCH40 1.25"

The rotor is putting out around 2.5GPM according to the nozzle. I assume it's probably 250" total distance from the water meter.


User avatar

g-man
Moderator
Posts: 14686
Joined: Wed Jun 14, 2017 10:32 pm
Location: Fishers, IN
Grass Type: Front: NoMix Back: Bewitched
Lawn Size: 5678
Mower: John Deere 220E

Re: Swing pipe max length

Post by g-man »

1/2in funny pipe at 2.50gpm for 15ft. I would not do this. I don't remember the id of the funny pipe, but the speed and pressure loss will be high.

I'm not clear how you will route the funny pipe without digging around the tree. It seems harder to go this way. In your diagram, water flows from 2 to 1? If so, I would just tap into that PVC closer to rotor 2 at 45 degrees to the new head using 1/2 polypipe (safe to 6gpm). Leave the other pipe to rotor 1 buried.


Greendoc
TLF Supporter
Posts: 3388
Joined: Sat Mar 24, 2018 5:52 pm
Location: Hawaii
Grass Type: All warm season turf
Lawn Size: Acres
Mower: Toro GM 1000

Re: Swing pipe max length

Post by Greendoc »

No more than 24" of swing pipe or pressure losses will be very high. I use this flexible piping that can have standard PVC fittings cemented onto it called spa flex around trees.


Topic Author

Movingshrub
Posts: 3266
Joined: Mon Jun 12, 2017 11:31 am
Location: Huntsville, AL
Grass Type: TifTuf Bermuda
Lawn Size: 13,000 SQFT
Mower: Honda Rotary & JD 220A Reel

Re: Swing pipe max length

Post by Movingshrub »

My concern is having to dig it all up again if the tree goes away. I am considering a T, a stub, then a 45 towards the front of the tree, and then moving the rotor to the front. The follow up to that would be putting a plastic cap on the existing swing joint feeding rotor 1 or putting a plug into the threaded opening that feeds the swing joint for rotor 1.


User avatar

g-man
Moderator
Posts: 14686
Joined: Wed Jun 14, 2017 10:32 pm
Location: Fishers, IN
Grass Type: Front: NoMix Back: Bewitched
Lawn Size: 5678
Mower: John Deere 220E

Re: Swing pipe max length

Post by g-man »

I do have to confess on using funny pipe for 15 feet in the past. But it was for a mp strip with 0.2gpm. At this low flow, it worked. I was just tired of digging and it was the last head.


Topic Author

Movingshrub
Posts: 3266
Joined: Mon Jun 12, 2017 11:31 am
Location: Huntsville, AL
Grass Type: TifTuf Bermuda
Lawn Size: 13,000 SQFT
Mower: Honda Rotary & JD 220A Reel

Re: Swing pipe max length

Post by Movingshrub »

The ID of the tube is 0.487". The closest item on the design manual is SCH 80
1/2" with and ID of 0.546". This says SCH 80 would lose 3psi per 100 feet. Even thought it may not be the right approach - How is 15 of swing pipe at all concerning for pressure drop? It's pushing 2 GPM.

Image

Last edited by Movingshrub on Tue Aug 07, 2018 10:43 pm, edited 1 time in total.


User avatar

Rain Bird Corp
Posts: 35
Joined: Wed Jun 06, 2018 10:27 am
Location: Worldwide
Grass Type: All Types
Lawn Size: ???
Mower: ????

Re: Swing pipe max length

Post by Rain Bird Corp »

Movingshrub wrote: ↑

Tue Aug 07, 2018 6:53 pm

@Rain Bird Corp I am trying to use some swing pipe type tubing to move a 5000 series rotor from behind a tree. I initially planned to remove the tree. The plan changed. Is there a max length of run and/or a friction pressure loss chart. I called rainbird tech support and couldn't get an answer after being on hold for 15 minutes. Can you help me out on this?

Swing pipe was not envisioned to be used in lengths over a foot or two. So, we do not generate flow loss data for the product. Consider using pipe for lengths over a foot or two.

Ron Wolfarth
Rain Bird Corporation
6991 E. Southpoint Road
Tucson, Arizona 85756


Topic Author

Movingshrub
Posts: 3266
Joined: Mon Jun 12, 2017 11:31 am
Location: Huntsville, AL
Grass Type: TifTuf Bermuda
Lawn Size: 13,000 SQFT
Mower: Honda Rotary & JD 220A Reel

Re: Swing pipe max length

Post by Movingshrub »

Rain Bird Corp wrote: ↑

Wed Aug 08, 2018 10:51 am

Movingshrub wrote: ↑

Tue Aug 07, 2018 6:53 pm

@Rain Bird Corp I am trying to use some swing pipe type tubing to move a 5000 series rotor from behind a tree. I initially planned to remove the tree. The plan changed. Is there a max length of run and/or a friction pressure loss chart. I called rainbird tech support and couldn't get an answer after being on hold for 15 minutes. Can you help me out on this?

Swing pipe was not envisioned to be used in lengths over a foot or two. So, we do not generate flow loss data for the product. Consider using pipe for lengths over a foot or two.